Skip links

Splash isolation cover for VD furnace

Application Industry: Refractories for Steel Industry

Application Equipment: VD Vacuum Refining Furnace Cover and Splash Guard

Size: Custom splash isolation cover geometry per VD furnace design (free engineering on request)

Consultation:
Share:

Products Overview

Our Splash isolation cover for VD furnace is a high-performance refractory product engineered for VD furnace cover and splash guard service. The product family is manufactured from high-quality corundum as main raw materials with steel fibre reinforced ultra-low cement castable production process. The product family features good thermal shock resistance, erosion resistance, and no spalling for VD furnace cover and splash guard service, with excellent service performance.

The Splash isolation cover for VD furnace product family is offered in three engineering-proven VD chemistry grades. The CH-VD85 grade features MgO+Al2O3 content minimum 85% for general VD furnace cover and splash guard service. The CH-VD90 grade features MgO+Al2O3 content minimum 90% for higher-demand VD furnace cover and splash guard service. The CH-VD92 grade features MgO+Al2O3 content minimum 92% and Cr2O3 content minimum 2% for highest-demand VD furnace cover and splash guard service. All three grades deliver Bulk Density minimum 2.90 to 3.05 g/cm³, Cold Crushing Strength minimum 40 MPa after 110 °C curing for 24 hours and minimum 60 MPa after 1500 °C firing for 3 hours, and Permanent Linear Change ±0.5 percent after 1500 °C firing for 3 hours.

Sourced from our Xinmi City, Zhengzhou, Henan, China facility, each Splash isolation cover for VD furnace grade is engineered to ASTM, GB/T, and ISO refractory standards. For an overview of the broader catalogue, see the Refractories for the Steel Industry category, or contact our technical sales team for a free consultation against your refractory drawing.

Product Features

Features:

  1. Manufactured from high-quality corundum as main raw materials with steel fibre reinforced ultra-low cement castable production process
  2. Engineering-proven good thermal shock resistance, erosion resistance, and no spalling for VD furnace cover and splash guard service
  3. Designed for VD furnace cover and VD furnace splash guard service zones with high service life performance
  4. Three VD chemistry grades covering MgO+Al2O3 content 85%-92% and Cr2O3 content minimum 2% for highest-demand VD furnace service
  5. Custom VD furnace cover and splash guard design available for different vacuum refining furnace capacity and steel grade service

Product Specification

The refractory is made by steel fibre reinforced ultra-low cement castables with corundum as main materials, and characterized as good thermal shock resistance, erosion resistance, and no spalling in use.

Brands
Items
CH-VD85 CH-VD90 CH-VD92
MgO+Al2O3 (%) ≥ 85 ≥ 90 ≥ 92
Cr2O3 (%) ≥ 2
Bulk density (g/cm³) ≥ 2.90 ≥ 3.05 ≥ 3.0
Cold crushing strength (MPa) ≥ 40
(110 °C, 24h)
≥ 40
(110 °C, 24h)
≥ 40
(110 °C, 24h)
≥ 60
(1500 °C, 3h)
≥ 60
(1500 °C, 3h)
≥ 60
(1500 °C, 3h)
Permanent linear change (%) ± 0.5
(1500 °C, 3h)
± 0.5
(1500 °C, 3h)
± 0.5
(1500 °C, 3h)

Note: Five performance parameters specified: MgO+Al2O3 content, Cr2O3 content, Bulk density, Cold crushing strength, and Permanent linear change. Three VD chemistry grades engineered for VD furnace cover and VD furnace splash guard service. For project-specific chemistry and geometry, contact CH Refractories engineering.

Product Applications

Splash isolation cover for VD furnace is a high-performance refractory product manufactured from high-quality corundum as main raw materials with steel fibre reinforced ultra-low cement castable production process, engineered for VD furnace cover and splash guard service. The product family features good thermal shock resistance, erosion resistance, and no spalling for VD furnace cover and splash guard service, with excellent service performance.

Application Industry: Refractories for the Steel Industry and the broader Metallurgical Industry.

Target Equipment: VD Vacuum Refining Furnace Cover and Splash Guard of small, medium-size, and large VD furnaces in steelmaking secondary refining operations.

Specific Application Zones: The CH-VD85 grade (MgO+Al2O3 content minimum 85%) is the standard variant for general VD furnace cover and splash guard service. The CH-VD90 grade (MgO+Al2O3 content minimum 90%) is the higher-demand variant for VD furnace cover and splash guard service. The CH-VD92 grade (MgO+Al2O3 content minimum 92% and Cr2O3 content minimum 2%) is the highest-demand variant for VD furnace cover and splash guard service. All three grades deliver Bulk Density minimum 2.90 to 3.05 g/cm³, Cold Crushing Strength minimum 40 MPa after 110 °C curing and minimum 60 MPa after 1500 °C firing, and Permanent Linear Change ±0.5 percent after 1500 °C firing for 3 hours.

CH Refractories is a Splash isolation cover for VD furnace manufacturer in China, Henan, Zhengzhou. The complete Splash isolation cover for VD furnace product family is manufactured in our Xinmi City, Zhengzhou, Henan, China facility to ASTM, GB/T, and ISO refractory standards. Each batch is supported by free consultation, on-site technical support, and a dedicated engineering team serving Refractories for the Steel Industry customers across the global iron and steel value chain.

Product FAQ

A1: Splash isolation cover for VD furnace is a high-performance refractory product engineered for VD furnace cover and splash guard service. The product family is manufactured from high-quality corundum as main raw materials with steel fibre reinforced ultra-low cement castable production process. The product family features good thermal shock resistance, erosion resistance, and no spalling for VD furnace cover and splash guard service, with excellent service performance.

A2: CH Refractories offers three engineering-proven VD chemistry grades of Splash isolation cover for VD furnace. The CH-VD85 grade features MgO+Al2O3 content minimum 85% for general VD furnace cover and splash guard service. The CH-VD90 grade features MgO+Al2O3 content minimum 90% for higher-demand VD furnace cover and splash guard service. The CH-VD92 grade features MgO+Al2O3 content minimum 92% and Cr2O3 content minimum 2% for highest-demand VD furnace cover and splash guard service.

A3: Splash isolation cover for VD furnace delivers Bulk Density minimum 2.90 to 3.05 g/cm³ depending on grade. Cold Crushing Strength is minimum 40 MPa after 110 °C curing for 24 hours and minimum 60 MPa after 1500 °C firing for 3 hours. Permanent Linear Change is ±0.5 percent after 1500 °C firing for 3 hours. The product family features good thermal shock resistance, erosion resistance, and no spalling for VD furnace cover and splash guard service.

A4: Yes. CH Refractories offers custom chemistry, geometry, and grade optimization against the buyer's specific VD furnace cover and splash guard design and steel grade production requirements. CH Refractories engineers can adjust MgO+Al2O3 content, Cr2O3 content, raw material formulation, steel fibre content, and binder system to meet specific VD furnace capacity and steel grade conditions. Please send the VD furnace drawing, splash isolation cover design, furnace capacity, and steel grade data to our engineering team in Xinmi City, Zhengzhou, Henan, China for a free consultation, on-site technical support, and a tailored splash isolation cover for VD furnace formulation proposal with optimized grade selection, raw material adjustment, and geometry design for your specific VD furnace service conditions.

Related Products

Leave Message






    This site is registered on portal.liquid-themes.com as a development site. Switch to production mode to remove this warning.